検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 90 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Pulsed muon facility of J-PARC MUSE

下村 浩一郎*; 幸田 章宏*; Pant, A. D.*; 砂川 光*; 藤森 寛*; 梅垣 いづみ*; 中村 惇平*; 藤原 理賀; 反保 元伸*; 河村 成肇*; et al.

Interactions (Internet), 245(1), p.31_1 - 31_6, 2024/12

J-PARC Muon Facility: MUSE (Muon Science Establishment) is responsible for the inter-university user program and the operation, maintenance, and construction of the muon beamlines, namely D-line, S-line, U-line, and H-line, along with the muon source at J-PARC Materials and Life Science Facility (MLF). In this paper, recent developments are briefly presented.

論文

Measurements of neutron total and capture cross sections of $$^{139}$$La and evaluation of resonance parameters

遠藤 駿典; 河村 しほり*; 奥平 琢也*; 吉川 大幹*; Rovira Leveroni, G.; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之

European Physical Journal A, 59(12), p.288_1 - 288_12, 2023/12

 被引用回数:0 パーセンタイル:0.02(Physics, Nuclear)

ランタン(La)-139の断面積と共鳴パラメータは、原子力分野への応用や基礎核物理の研究にとって重要である。本論文では、大強度陽子加速器施設(J-PARC)のANNRIにてLaの中性子全断面積と捕獲断面積を測定した。Negative共鳴を含む4つの共鳴の共鳴パラメータを、共鳴解析コードREFITを用いて求めた。その結果いくつかの共鳴パラメータにおいて、評価済み核データライブラリとの不一致が見られた。さらに全断面積を再現するために、スピン依存する散乱半径もフィットした。得られた散乱半径は、評価済み核データライブラリで記録されたものよりも大きいことがわかった。

論文

J-PARC ANNRIビームラインにおける偏極熱外中性子利用

遠藤 駿典; 奥平 琢也*

波紋, 33(2), p.68 - 72, 2023/05

J-PARC・MLFに設置されている中性子ビームラインの一つであるANNRIでは、Ge検出器、NaI検出器、LaBr検出器などのガンマ線検出器を用いた核反応測定が行われている。さらに近年、偏極中性子生成デバイスであるHeスピンフィルタをANNRIにおいて導入可能となり、偏極中性子を用いた新たな核反応測定が行われるようになった。$$^{117}$$Snなどのp波共鳴において、中性子の偏極方向とガンマ線の放出方向に依存する断面積の測定が行われた。また偏極中性子と円偏光度測定を組み合わせた新たな核データや角相関項の測定が今後行われていく予定である。本稿ではこれらANNRIにおける偏極中性子利用に関しての現状について解説する。

論文

Covariance of resonance parameters ascribed to systematic uncertainties in experiments

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.

EPJ Web of Conferences, 281, p.00012_1 - 00012_5, 2023/03

In resonance analysis, experimental uncertainties affect the accuracy of resonance parameters. A resonance analysis code REFIT can consider the statistical uncertainty of the experimental data in evaluation of the resonance parameter uncertainty. On the other hand, since the systematic uncertainties of the sample thickness and normalization, which is proportional to the cross-section, are not independent at each measurement point, they must be treated differently from the statistical uncertainty. However, their treatment has not been discussed in detail so far. In this study, we evaluated the effect of the systematic uncertainties of experimental data on deduced resonance parameters by varying sample-thickness values used for the REFIT code. Covariance of resonance parameters ascribed to systematic uncertainties were evaluated from the neutron transmission data of natural zinc measured at the J-PARC MLF ANNRI. We will introduce this evaluation method and discuss the feature of obtained correlations.

論文

Present status of J-PARC MUSE

下村 浩一郎*; 幸田 章宏*; Pant, A. D.*; 名取 寛顕*; 藤森 寛*; 梅垣 いづみ*; 中村 惇平*; 反保 元伸*; 河村 成肇*; 手島 菜月*; et al.

Journal of Physics; Conference Series, 2462, p.012033_1 - 012033_5, 2023/03

 被引用回数:0 パーセンタイル:0.21(Physics, Applied)

At J-PARC MUSE, since the $$mu$$SR2017 conference and up to FY2022, there have been several new developments at the facility, including the completion of a new experimental area S2 at the surface muon beamline S-line and the first muon beam extraction to the H1 area in the H-line, mainly to carry out high-statistics fundamental physics experiments. Several new studies are also underway, such as applying negative muon non-destructive elemental analysis to the analysis of samples returned from the asteroid Ryugu in the D2 area of the D-line. This paper reports on the latest status of MUSE.

論文

Automated pulsed magnet system for neutron diffraction experiments at the Materials and Life Science Experimental Facility in J-PARC

渡辺 真朗; 木原 工*; 野尻 浩之*

Quantum Beam Science (Internet), 7(1), p.1_1 - 1_10, 2023/03

J-PARC物質・生命科学実験施設において、ユーザーが使いやすく、かつ新しい試料環境装置として35Tまで発生可能なパルスマグネットシステムを開発した。これは、真空チャンバー、GM冷凍機、小型ソレノイドコイルを挿入したSUS管で構成されている。コイルは液体窒素自動供給装置から供給される液体窒素で冷却され、試料はGM冷凍機で冷却される。この組み合わせにより、ユーザー操作のための自動運転可能な強磁場回折測定が容易になる。散乱角は最大42度で、これまでの装置よりも大幅に広くなっている。中性子回折実験は、マルチフェロイック物質(TbMnO$$_{3}$$)を用いて、回折ピークの磁場依存性が明確に観察された。このようにユーザープログラム用の実用的な強磁場回折のための、新しいパルスマグネットシステムが確立された。

論文

Measurements of the neutron total and capture cross sections and derivation of the resonance parameters of $$^{181}$$Ta

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.; 藤 暢輔; 瀬川 麻里子; 前田 亮

Nuclear Science and Engineering, 18 Pages, 2023/00

 被引用回数:1 パーセンタイル:68.31(Nuclear Science & Technology)

The neutron transmission ratio and capture yield for $$^{181}$$Ta were measured in J-PARC MLF ANNRI to improve the accuracy of resonance parameters. The total cross section was determined from the transmission ratio in the energy range from 0.2 to 150 eV. The capture cross section was obtained from the capture yield using the pulse height weighting technique (PHWT) in the energy range from thermal to 150 eV. The obtained transmission ratio and capture cross-section were fitted by the resonance analysis code, REFIT, and the resonance parameters were determined below 150 eV. It was also discussed the correlations caused by fitting based on statistical uncertainty and correlations for systematic uncertainty based on sample thickness in the transmission measurements.

論文

Measurement of the transverse asymmetry of $$gamma$$ rays in the $$^{117}$$Sn($$n,gamma$$)$$^{118}$$Sn reaction

遠藤 駿典; 奥平 琢也*; 安部 亮太*; 藤岡 宏之*; 広田 克也*; 木村 敦; 北口 雅暁*; 奥 隆之; 酒井 健二; 嶋 達志*; et al.

Physical Review C, 106(6), p.064601_1 - 064601_7, 2022/12

 被引用回数:3 パーセンタイル:49.92(Physics, Nuclear)

熱外中性子入射により形成される複合核において観測された、空間反転対称性の破れの大きな増幅は、今のところ複合核状態の入射チャネルにおけるパリティの異なる部分波の混合の結果として説明されている。さらに時間反転対称性の破れも同様のメカニズムで増幅されることが示唆されている。この入射チャネルにおける混合は、複合核共鳴から放出される個々のガンマ線のエネルギー依存なスピン-角相関を引き起こす。本研究ではJ-PARC・MLF・ANNRIにて偏極熱外中性子ビームを用い、$$^{117}$$Sn($$n,gamma$$)$$^{118}$$Sn反応におけるガンマ線強度分布が、中性子の偏極方向に依存することを確認した。

論文

Angular distribution of $$gamma$$ rays from the $$p$$-wave resonance of $$^{118}$$Sn

古賀 淳*; 高田 秀佐*; 遠藤 駿典; 藤岡 宏之*; 広田 克也*; 石崎 貢平*; 木村 敦; 北口 雅暁*; 新實 裕大*; 奥平 琢也*; et al.

Physical Review C, 105(5), p.054615_1 - 054615_5, 2022/05

 被引用回数:4 パーセンタイル:64.25(Physics, Nuclear)

J-PACR MLFのパルス中性子源及びBL04 ANNRIに設置されたゲルマニウム検出器を用いて、$$^{117}$$Sn(n,$$gamma$$)反応により生じるガンマ線の中性子エネルギー依存する角度分布を測定した。$$^{117}$$Snの複合核状態から$$^{118}$$Snの基底状態への遷移で発生する9327keVのガンマ線に関して、角度によって1.33eVの$$p$$波共鳴の形状が変わることが明らかに確認できた。この共鳴の低エネルギー側の積分値と高エネルギー側の積分値をそれぞれ$$N_{L}, N_{H}$$で表したとき、非対称性$$A_{LH}=(N_{L}-N_{H})/(N_{L}+N_{H})$$$$A$$cos$$theta_{gamma}+B$$という角度依存をし、それぞれのパラメータ値が$$A=0.394pm0.073$$$$B=0.118pm0.029$$であることがわかった。

論文

Neutron capture and total cross-section measurements and resonance parameter analysis of niobium-93 below 400 eV

遠藤 駿典; 木村 敦; 中村 詔司; 岩本 修; 岩本 信之; Rovira Leveroni, G.; 寺田 和司*; 明午 伸一郎; 藤 暢輔; 瀬川 麻里子; et al.

Journal of Nuclear Science and Technology, 59(3), p.318 - 333, 2022/03

 被引用回数:6 パーセンタイル:64.12(Nuclear Science & Technology)

In order to improve the accuracy of the cross-section and the resonance parameters of $$^{93}$$Nb, neutron capture and total cross-sections were measured using the J-PARC MLF ANNRI. The thermal-neutron capture cross-section was deduced as 0.97$$pm$$0.12 b. The resonance parameters of 11 resonances below 400 eV were determined from obtained capture cross-sections and transmission ratios by using the resonance analysis code, REFIT.

報告書

J-PARC物質・生命科学実験施設(MLF)及び関連設備の現状と高度化戦略

勅使河原 誠; 中村 充孝; 金正 倫計; 曽山 和彦

JAEA-Technology 2021-022, 208 Pages, 2022/02

JAEA-Technology-2021-022.pdf:14.28MB

J-PARCの定格出力1MWの物質・生命科学実験施設において、今後の具体的かつ現実的な高度化戦略を展開するため、線源性能に大きく影響する加速器技術(リニアックおよびRCS)、線源技術、中性子・ミュオン輸送技術、検出技術、そしてそれらが結実する中性子・ミュオン ビーム利用装置等の現状(所期設計値に対する到達度)について整理した。さらに、現状分析に基づき出力増強に向けた改良点等について報告する。

論文

KeV-region analysis of the neutron capture cross-section of $$^{237}$$Np

Rovira Leveroni, G.; 片渕 竜也*; 登坂 健一*; 松浦 翔太*; 児玉 有*; 中野 秀仁*; 岩本 修; 木村 敦; 中村 詔司; 岩本 信之

Journal of Nuclear Science and Technology, 59(1), p.110 - 122, 2022/01

 被引用回数:3 パーセンタイル:44.61(Nuclear Science & Technology)

Neutron capture cross-section measurements for $$^{237}$$Np have been conducted with the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) at the Materials and Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC) using neutrons with energy ranging from thermal energy to 1 MeV. A Time of Flight (TOF) method using a NaI(Tl) detector was employed for these measurements and the data were analyzed based on the pulse-height weighting technique in order to derive the neutron capture cross-section. The absolute capture cross-section was determined using the whole shape of the first resonance from JENDL-4.0 together with the total neutron flux derived from a $$^{197}$$Au sample measurement in which the first resonance was completely saturated. Both normalization techniques present agreement within 2%. The present results are also compared evaluated data libraries. There is a discrepancy of 10-25% discrepancy from 0.5 to 20 keV with JENDL-4.0. Nonetheless, above this energy, the JENDL-4.0 seems to reproduce the present data better as the results agree within uncertainties up to 500 keV. The cross-section results contain errors below 4% from 0.5 to 30 keV. However, the total uncertainty increases to over 8% over that energy. Along with the cross section measurement, theoretical calculations were performed to reproduce the present results.

論文

Dependence of charge-exchange efficiency on cooling water temperature of a beam transport line

山本 風海; 畠山 衆一郎; Saha, P. K.; 守屋 克洋; 岡部 晃大; 吉本 政弘; 仲野谷 孝充; 藤来 洸裕; 山崎 良雄; 菅沼 和明

EPJ Techniques and Instrumentation (Internet), 8(1), p.9_1 - 9_9, 2021/07

J-PARC 3GeVシンクロトロン(RCS)は最大1MWの高出力陽子ビームを中性子ターゲットに供給している。稼働率を向上し実験成果の最大化を図るために、RCSではさまざま運転パラメータの履歴を記録しているが、そのデータのうち入射効率と入射ビームラインの磁石を冷却している冷却水温度が同期していることを発見した。RCS入射時に、入射負水素(H$$^{-}$$)ビームは炭素薄膜を通過し陽子に変換されるので、入射効率が変動しているという事は陽子への変換効率が冷却水温度に依存していることを示している。ビーム形状,薄膜の条件等から、入射ビームのフォイルへの入射位置が0.072mm程度振動していて、それが磁石磁場の変動に換算して1.63$$times$$10$$^{-5}$$となることを求めた。この値は、単純に磁石が冷却水の温度変動に従って伸び縮みするとして評価した結果とファクタ程度で一致し、変換効率の変動の主要因は磁場変動であることが確認できた。

論文

Neutron capture cross sections of curium isotopes measured with ANNRI at J-PARC

川瀬 頌一郎*; 木村 敦; 原田 秀郎; 岩本 信之; 岩本 修; 中村 詔司; 瀬川 麻里子; 藤 暢輔

Journal of Nuclear Science and Technology, 58(7), p.764 - 786, 2021/07

 被引用回数:2 パーセンタイル:30.55(Nuclear Science & Technology)

The neutron capture cross sections of $$^{244}$$Cm and $$^{246}$$Cm were measured for the neutron energy range of 1-1000 eV via the neutron time-of-flight method with ANNRI at MLF of the J-PARC. The world's most intense neutron pulses from the Japan Spallation Neutron Source enable the accurate measurement of neutron capture cross sections. Besides, single-bunched neutron pulses allow the analysis in a higher neutron energy region than the previous measurement at ANNRI. The resonance analyses were performed up to 1000 eV by using a resonance shape analysis code REFIT. The spectra of prompt gamma-rays from neutron capture reactions of $$^{244}$$Cm and $$^{246}$$Cm were also obtained, and 43 and 10 prompt gamma-ray peaks from $$^{244}$$Cm(n,$$gamma$$) and $$^{246}$$Cm(n,$$gamma$$) reactions were newly observed, respectively.

論文

Isomer production ratio of the $$^{112}$$Cd($$n,gamma$$)$$^{113}$$Cd reaction in an $$s$$-process branching point

早川 岳人*; 藤 暢輔; 木村 敦; 中村 詔司; 静間 俊行*; 岩本 信之; 千葉 敏*; 梶野 敏貴*

Physical Review C, 103(4), p.045801_1 - 045801_5, 2021/04

 被引用回数:1 パーセンタイル:0.02(Physics, Nuclear)

A $$beta$$-decay unstable isomer with a half-life of 14.1 y at 264 keV in $$^{113}$$Cd is a branching point in the $$s$$ process, from which a weak branch reaches to a rare tin isotope $$^{115}$$Sn whose astrophysical origin has been an open problem. We have measured $$gamma$$ rays decaying to the ground state or the isomer in the $$^{112}$$Cd($$n,gamma$$)$$^{113}$$Cd reaction using high-energy resolution detectors in conjunction with a time-of-flight method. The relative production ratios of the isomer to the total following the neutron capture reactions on $$^{112}$$Cd have been evaluated in an energy region of up to 9 keV, and the spin and parity of several resonances have been assigned.

論文

Upgrade history and present status of the general control system for the Materials and Life Science Experimental Facility at J-PARC

酒井 健二; 大井 元貴; 羽賀 勝洋; 甲斐 哲也; 中谷 健; 小林 庸男*; 渡邊 聡彦*

JPS Conference Proceedings (Internet), 33, p.011151_1 - 011151_6, 2021/03

核破砕中性子源やミュオン標的などを安全に効率よく運転するために、物質・生命科学実験施設(MLF)は、専用の全体制御システム(GCS)を持ち、運転状況に応じた機器の監視操作やインターロックを運用している。GCSはネットワーク系(LAN),統括制御系(ICS),インターロック系(ILS),共用サーバー,タイミング配信系(TDS)など幾つかのサブシステムで構成される。GCSはMLFのターゲットステーションを独自に運転制御する一方、J-PARCの加速器や他実験施設と連動しながらMLFの安定したビーム運転を実現している。2008年度のビーム運転開始以来、GCSは運転制御コミッショニングに基づく改修を経て、システム性能を継続的に維持する視点から、ICSの大幅なアップグレードやILSの機能拡張を2015年度ぐらいまで実施してきた。近年は、制御機器の生産・サポート終了に伴い後継機種への更新を進めている。この様に運転開始から、GCSには全般に渡って数多くの追加・変更がなされてきた。この様な状況下で、これまでのGCSの高度化の履歴と現況を把握することは、GCSの今後の方向性を決める上で重要である。本報告ではGCSの高度化の履歴,現状、及び今後の課題について議論する。

論文

Measurement of single-event upsets in 65-nm SRAMs under irradiation of spallation neutrons at J-PARC MLF

黒田 順也*; 真鍋 征也*; 渡辺 幸信*; 伊東 功次郎*; Liao, W.*; 橋本 昌宜*; 安部 晋一郎; 原田 正英; 及川 健一; 三宅 康博*

IEEE Transactions on Nuclear Science, 67(7), p.1599 - 1605, 2020/07

 被引用回数:4 パーセンタイル:44.4(Engineering, Electrical & Electronic)

半導体デバイスの信頼性の観点から、環境放射線起因ソフトエラーは問題となる。ソフトエラー発生率(SER: Soft Error Rate)を実測的に評価するために、中性子照射施設にてデバイスへの中性子照射測定実験が一般的に行われる。我々はこれまでに大阪大学のRCNPおよび東北大学のCYRICにて、65nmバルクSRAMおよびSOTB SRAMを対象とした中性子照射SER測定実験を行った。本研究では、同じデバイスを用いて、J-PARC MLFにある大強度の核破砕中性子源のBL10でSER測定実験を実施した。その結果、動作電圧を低くした際のSERの増加割合が、他の施設での測定結果と比べて高いことが判明した。PHITSによる解析の結果、入射中性子と保護樹脂に含まれる水素原子との弾性散乱による二次陽子が原因で動作電圧の低い条件下でSERが増加することを明らかにした。

報告書

平成30年度研究開発・評価報告書 評価課題「J-PARCに関する研究開発」(中間評価)

J-PARCセンター

JAEA-Evaluation 2019-003, 52 Pages, 2019/06

JAEA-Evaluation-2019-003.pdf:6.61MB

日本原子力研究開発機構(以下、「原子力機構」という)は、「国の研究開発評価に関する大綱的指針」(平成28年12月21日内閣総理大臣決定)及びこの大綱的指針を受けて作成された「文部科学省における研究及び開発に関する評価指針」(平成29年4月1日文部科学大臣決定)、並びに原子力機構の「研究開発課題評価実施規程」(平成17年10月1日制定)等に基づき、平成31年3月1日に第3期中長期計画に対する中間評価をJ-PARC研究開発・評価委員会に諮問した。これを受けて、J-PARC研究開発・評価委員会は、委員会において定められた評価方法に従い、原子力機構から提出されたJ-PARC研究開発の実施に関する説明資料の検討及びJ-PARCセンター長並びにディビジョン長による口頭発表と質疑応答を実施した。本報告書は、J-PARC研究開発・評価委員会より提出された中間評価の内容をまとめるとともに、「評価結果(答申書)」を添付したものである。

報告書

J-PARC物質・生命科学実験施設の全体制御システムの進捗状況

酒井 健二; 大井 元貴; 高田 弘; 甲斐 哲也; 中谷 健; 小林 庸男*; 渡邊 聡彦*

JAEA-Technology 2018-011, 57 Pages, 2019/01

JAEA-Technology-2018-011.pdf:4.98MB

核破砕中性子源やミュオン標的などを安全に効率よく運転するために、物質・生命科学実験施設(MLF)は、専用の全体制御システム(GCS)を持ち、運転状況に応じた機器の監視操作やインターロックを運用している。GCSは、その役割に応じて、ネットワーク系(LAN), 統括制御系(ICS), サーバー, インターロック系(ILS), タイミング配信系(TDS)など幾つかのサブシステムで構成される。GCSは、MLF内の機器を独自に運転制御する一方、J-PARCの加速器や他実験施設と連動しながらMLFの安定したビーム運転を実現している。2008年度のビーム運転開始以来、GCSは運転制御コミッショニングに基づく改修を経て、システム性能を継続的に維持する視点から、ICSの大幅なアップグレードやILSの機能拡張を実施してきた(2010年度-2015年度)。この様に運転開始から約10年間、GCSには全般に渡って数多くの追加・変更がなされてきた。したがってGCS高度化の今後の方向性を決めるために、これまでの高度化の履歴とGCSの現況を把握することが重要と考え、2017年度時のGCSの構成・機能・役割を整理して取り纏めた。

論文

Recovery of helium refrigerator performance for cryogenic hydrogen system at J-PARC MLF

麻生 智一; 勅使河原 誠; 長谷川 勝一; 武藤 秀生; 青柳 克弘; 野村 一隆; 高田 弘

Journal of Physics; Conference Series, 1021(1), p.012085_1 - 012085_4, 2018/06

BB2016-1899.pdf:0.54MB

 被引用回数:0 パーセンタイル:0.11(Nuclear Science & Technology)

At J-PARC's pulsed spallation neutron source, a cryogenic hydrogen system has been operated to provide liquid para-hydrogen (20K and 1.5 MPa) to the moderators since 2008. Typical operating period of the cryogenic hydrogen system was approximately 3 months continuously. However, the pressure differences between No.1, No.2 heat exchangers (HXs) and an adsorber (ADS) in the helium refrigerator had begun to increase rapidly since the beginning of 2015, the refrigerator could not be operated continuously. The impurity in the refrigerator was measured by newly introduced quadrat mass spectrometer, but no significant impurities was observed. We suspected the oil contamination from the helium compressor, as it caused performance degradation of the cryogenic system in other facilities, such as RIKEN, CERN, etc. In the summer outage in 2016, we cleaned the HXs with Freon to remove the oil contamination, and replaced the activate charcoals of ADS and oil separator (OS-5). As a result, the performance of the helium refrigerator was recovered completely.

90 件中 1件目~20件目を表示